Sika® Raingard 18 LTR
Product details of Sika® Raingard
- 3 in 1 Acrylic Waterproof, Weatherproof & Heatproof Coating
- Flexible, liquid applied waterproofing membrane for all types of exposed roof slabs, terraces (sloped and flat), cement board, plastered surfaces, corrugated sheets etc.
- Provides excellent waterproofing properties
- UV Protection & Heat-proofing
- Can be applied directly or in combination of fabric/fiber
- Appearance /Colors: Sika® Raingard: White
- Packaging: 18kg
- Two coats of Sika Raingard (0.05 kg per Sq. ft)
- Storage Conditions: Best before 6 months if stored properly in undamaged and unopened original pack.
- Shelf-Life: Sealed packaging in dry and cool conditions at 5°C-30°C Liquid component must be protected from frost, direct UV exposure and sunlight.
Sika® Raingard is a flexible, liquid applied, single component, ultra violet rays and weather resistant, acrylic waterproofing membrane for all types of exposed roof slabs(new and old),terraces(sloped and flat),etc.
USES
Sika Raingard can be used for:
- Exposed roof waterproofing
- Impervious coating on roofs (flat and sloped) and concrete structures
- On non-trafficked areas
- Excellent adhesion to concrete, brickwork, corrugated asbestos, and asbestos cement sheet.
ADVANTAGES
- Crack-bridging upto 2mm
- Flexible
- Simple application (even at detailing) with roller and brush
- Economical and durable
- Bonds well to all types of masonry substrate
- Ultra violet rays and weather resistant
- Algae and fungi resistant
- Heat resistant
METHOD OF APPLICATION
Substrate preparation
The cementitious substrate should be sound and of sufficient strength (min. 25 N/mm²). Minimum pull-off strength 1.5 N/mm², it should be free from grease, oil and contamination.
Priming:
Prime the prepared substrate with Sika® Raingard Primer by brush or roller.
Application:
Sika® Raingard is supplied in a single component pack and is in ready to use form. Stir thoroughly before application. Within 45 minutes of priming apply 1st coat of Sika® Raingard by brush or roller. Apply the 2nd and 3rd coat of Sika® Raingard following the same above procedure at suitable time interval of 24 hours between the two coats.
Waiting Time /Waiting time between coats
Overcoating +30°C 24 hours
Technical Data
Layer Thickness: With Sika® Fab-1 ~1.2 mm
Service Temperature: +5 ºC to +45ºC Crack bridging 2 mm (According to ASTM C 1305 - 06) properties.
Workable time: 15 minutes at +27º C
Tack free time: 25 minutes at +27º C
Water permeability: Passes System Structure
Layer thickness: 1.2 mm
Primer:
1 x Sika® Raingard (diluted with 20% water)
First Coat:
1 x Sika® Raingard
Fabric reinforcement :
1 x Sika® Fab 1
Second Coat:
1x Sika® Raingard
Top Coat:
1x Sika® Raingard Application Details
Consumption / Dosage
Sika® Raingard Primer : 0.200 kg/m2 per coat depending on the substrate. Sika® Raingard: 0.5 kg /m2 per coat (2-3 coats recommended)
Total thickness – 1.2 mm approx. with Sika® Fab1 and 1mm without Sika® Fab1.
Specifications of Sika® Raingard
- Brand SIKA
- SKU114700137_PK-1272810861
What’s in the box1x18 Kg Bucket.